All alarm codes
ALARM 3
EMERGENCY STOP (&0000FFBF)
Multiple possible causes — door interlock, drive ready signal missing, external E-stop loop break, chip conveyor, etc. The R69 interface signal byte indicate...
- Controls
- Mazatrol Matrix Nexus
- Machine series
- unspecified Matrix Nexus lathe
Causes
Multiple possible causes — door interlock, drive ready signal missing, external E-stop loop break, chip conveyor, etc. The R69 interface signal byte indicates which gate is open.
- Fabian Achavalyoutube
There are many problems that can cause an EMERGENCY STOP alarm. Understanding the alarm page message and the interface signals can help determine the cause.
- Fabian Achavalyoutube
How to clear it
- 1
Open the alarm page and read the &0000FFBF hex string; then open the diagnostics for R69 interface signals to identify which bit is asserted, and chase that physical interlock.
- Fabian Achavalyoutube
Understanding the alarm page message and the interface signals can help determine the cause.
- Fabian Achavalyoutube
Confidence: medium · Source explains the diagnostic *method* (R69 interface signals) but the specific physical fix depends on which bit is asserted — no single root cause.
First sourced: 5/21/2026