All alarm codes
ALARM 354
Cond.Missing (Set Up Switch)
Missing condition signal — PLC ladder coil F154 is not satisfied. On Matrix Nexus, controlled by PLC parameter RB30.3.
- Controls
- Mazatrol Matrix Nexus
- Machine series
- unspecified Matrix Nexus equipped lathe
Causes
Missing condition signal — PLC ladder coil F154 is not satisfied. On Matrix Nexus, controlled by PLC parameter RB30.3.
- Fabian Achavalyoutube
#354 Cond.Missing (Set Up Switch). Coil F154 on the PLC LADDER .PLC Parameter RB30.3
- Fabian Achavalyoutube
How to clear it
- 1
Open PLC LADDER, find coil F154, identify the failing input. If the Set Up Switch / option is intentionally disabled, enable parameter RB30.3 to bypass.
- Fabian Achavalyoutube
How to troubleshoot user alarm on PLC LADDER. How to enable PLC Parameter
- Fabian Achavalyoutube
Confidence: high · Dedicated walkthrough naming the exact coil (F154) and parameter (RB30.3); same author has the matching SmoothG case (8baKwX85K58).
First sourced: 5/21/2026