All alarm codes
ALARM 354

Cond.Missing (Set Up Switch)

Missing condition signal — PLC ladder coil F154 is not satisfied. On Matrix Nexus, controlled by PLC parameter RB30.3.

Controls
Mazatrol Matrix Nexus
Machine series
unspecified Matrix Nexus equipped lathe

Causes

  1. Missing condition signal — PLC ladder coil F154 is not satisfied. On Matrix Nexus, controlled by PLC parameter RB30.3.

    • Fabian Achavalyoutube
      #354 Cond.Missing (Set Up Switch). Coil F154 on the PLC LADDER .PLC Parameter RB30.3

How to clear it

  1. 1

    Open PLC LADDER, find coil F154, identify the failing input. If the Set Up Switch / option is intentionally disabled, enable parameter RB30.3 to bypass.

Confidence: high · Dedicated walkthrough naming the exact coil (F154) and parameter (RB30.3); same author has the matching SmoothG case (8baKwX85K58).