All alarm codes
ALARM 12
ABSOLUTE POSITION WARNING (battery low)
The absolute position detection system has detected abnormal data.
- Controls
- Matrix, Matrix 2
- Machine series
- Integrex, Quick Turn
Causes
The absolute position detection system has detected abnormal data.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
The absolute position detection system has detected abnormal data.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
How to clear it
- 1
The battery is running down. Require Mazak Technical Center or Technology Center to replace the battery.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
The battery is running down. Require Mazak Technical Center or Technology Center to replace the battery.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Confidence: high · Official Mazak Matrix manual.
First sourced: 5/21/2026
Related alarms
Same control or a nearby code on the same machine.
- Alarm 2EMERGENCY STOP (Hardware trouble)Matrix, Matrix 2
- Alarm 22AMPLIFIER NOT EQUIPPEDMatrix, Matrix 2
- Alarm 3EMERGENCY STOP (E-stop button pressed)Matrix, Matrix 2, T-32, Fusion 640T
- Alarm 9ABSOLUTE POSITION MALFUNCTIONMatrix, Matrix 2
- Alarm 101SOFT LIMITMatrix, Matrix 2
- Alarm 113OVER TRAVEL (hardware limit)Matrix, Matrix 2