All alarm codes
ALARM 2
EMERGENCY STOP (Hardware trouble)
Trouble has occurred in the hardware.
- Controls
- Matrix, Matrix 2
- Machine series
- Integrex, Quick Turn
Causes
Trouble has occurred in the hardware.
- PARAMETER LIST / ALARM LIST / M-CODE LIST for MAZATROL MATRIX (H740HA0030E)manual
Trouble has occurred in the hardware.
- PARAMETER LIST / ALARM LIST / M-CODE LIST for MAZATROL MATRIX (H740HA0030E)manual
How to clear it
- 1
Turn power off and then back on. If this does not clear the alarm status, require Mazak Technical Center or Technology Center to replace the defective hardware or cables.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Turn power off and then back on. If this does not clear the alarm status, require Mazak Technical Center or Technology Center to replace the defective hardware or cables.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Additional notes
Operator-side: cycle power once. Anything beyond that is a service call.
Confidence: high · Direct quote from official Mazak Matrix manual (H740HA0030E).
First sourced: 5/21/2026
Related alarms
Same control or a nearby code on the same machine.
- Alarm 12ABSOLUTE POSITION WARNING (battery low)Matrix, Matrix 2
- Alarm 3EMERGENCY STOP (E-stop button pressed)Matrix, Matrix 2, T-32, Fusion 640T
- Alarm 9ABSOLUTE POSITION MALFUNCTIONMatrix, Matrix 2
- Alarm 101SOFT LIMITMatrix, Matrix 2
- Alarm 113OVER TRAVEL (hardware limit)Matrix, Matrix 2
- Alarm 131CUTTING FEED OVERRIDE ZEROMatrix, Matrix 2