All alarm codes
ALARM 22
AMPLIFIER NOT EQUIPPED
Amplifier power is not yet turned on. Or no signals are transferred yet. There is a discrepancy between the channel and rotary switch Nos. of the amplifier a...
- Controls
- Matrix, Matrix 2
- Machine series
- Integrex, Quick Turn, Variaxis
Causes
Amplifier power is not yet turned on. Or no signals are transferred yet. There is a discrepancy between the channel and rotary switch Nos. of the amplifier and the parameters concerned.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Amplifier power is not yet turned on. Or no signals are transferred yet. There is a discrepancy between the channel and rotary switch Nos. of the amplifier and the parameters concerned.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
How to clear it
- 1
Check for an incorrectly connected cable, an incorrectly attached connector, an inadequate input supply voltage to the amplifier, an incorrect axis-number switch setting, etc. Check the settings of parameters N17, N18, SA43, and SA44 for incorrectness.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Check for an incorrectly connected cable, an incorrectly attached connector, an inadequate input supply voltage to the amplifier, an incorrect axis-number switch setting, etc. Check the settings of parameters N17, N18, S…
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Confidence: high · Official Mazak Matrix manual with specific parameter numbers (N17, N18, SA43, SA44).
First sourced: 5/21/2026