Stop Spindle (rigid-tap tool data)
On a rigid-tap cycle the milling spindle never starts and Alarm 133 fires. The Tool Data 'holder type' setting being on 'fixed' for a rigid holder on Matrix ...
- Controls
- Matrix, Matrix 2
- Machine series
- Integrex
Causes
On a rigid-tap cycle the milling spindle never starts and Alarm 133 fires. The Tool Data 'holder type' setting being on 'fixed' for a rigid holder on Matrix 2 has been seen to suppress spindle start — switching to 'floating' allowed the cycle to run. (Other operators report 'fixed' is correct on their identical machine; Mazak tech said both are normal — likely a control option / parameter.)
- DKmachinistforum
It should run perfectly fine with the fixed tap option. Mine does and it's the same machine and control.
- DKmachinistforum
Generic cause from the Mazak manual entry: spindle rotation did not start when the rotation command was issued in auto operation; check the spindle amplifier and encoder.
- quoting the Mazak manualforum
Alarm 133 - STOP SPINDLE. Cause: Spindle rotation did not start when the spindle rotation start command was issued during automatic operation. Action: The spindle amplifier and the encoder must be checked for normal oper…
- quoting the Mazak manualforum
How to clear it
- 1
On Matrix 2 Integrex: open the Tool Data page for the offending tap, toggle holder type between 'fixed' and 'floating' to match how Mazak Tech configured your specific machine. Confirm spindle starts in single-block dry run before resuming.
- Goboforum
I changed it to "floating" and it works like it should. Just another one of those non-intuitive Mazak things.
- Goboforum
- 2
If the toggle does not resolve it, check the spindle amplifier and encoder per the manual.
- quoting the Mazak manualforum
The spindle amplifier and the encoder must be checked for normal operation.
- quoting the Mazak manualforum
Additional notes
Operators disagree on whether 'fixed' or 'floating' is the correct setting on identical Matrix 2 Integrex machines — likely an installed-option difference. The reliable diagnostic is to flip the setting and see if the spindle starts.
Confidence: medium · Two PM operators on identical Matrix 2 Integrex hardware report opposite correct settings. The fix (toggle holder type) is well-attested but the 'why' is not.
First sourced: 5/21/2026