All alarm codes
ALARM 35
OVERLOAD (servo)
An extraordinary overload has been detected.
- Controls
- Matrix, Matrix 2
- Machine series
- Quick Turn, Integrex, Slant Turn
Causes
An extraordinary overload has been detected.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
An extraordinary overload has been detected.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
How to clear it
- 1
Check if any collision has occurred on the machine and perform the corresponding recovery, or check and reduce the cutting conditions. If other measures should be taken, contact Mazak Technical Center or Technology Center with the information of the first item (Alarm No.) displayed in parentheses.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Check if any collision has occurred on the machine and perform the corresponding recovery, or check and reduce the cutting conditions.
- Mazatrol Matrix Alarm List, H740HA0030Emanual
Confidence: high · Official Mazak Matrix manual.
First sourced: 5/21/2026
Related alarms
Same control or a nearby code on the same machine.
- Alarm 101SOFT LIMITMatrix, Matrix 2
- Alarm 113OVER TRAVEL (hardware limit)Matrix, Matrix 2
- Alarm 131CUTTING FEED OVERRIDE ZEROMatrix, Matrix 2
- Alarm 3EMERGENCY STOP (E-stop button pressed)Matrix, Matrix 2, T-32, Fusion 640T
- Alarm 52BATTERY ALARM (NC memory backup)Matrix, Matrix 2, T-32
- Alarm 53NC TEMPERATURE WARNINGMatrix, Matrix 2