All alarm codes
ALARM 260

Slideway lubrication alarm

Pressure switch for slideway lubrication (SP67) did not turn on within a fixed time

Controls
T-Plus, T-32, T-32B, Fusion 640T
Machine series
Quick Turn, SQT, Nexus

Causes

  1. Pressure switch for slideway lubrication (SP67) did not turn on within a fixed time

  2. Low grease/lube level; clogged felt pickup filter at the bottom of plunger-type pumps (waxy buildup); kinked or crushed flexible distribution lines; worn pump piston

    • HelmanCNCindustry_blog
      Using a standard Way-lube can leave a waxy buildup in the tank bottom which eventually clogs the filter. Cleaning with varsol and air gun and reinstalling should improve pump performance.

How to clear it

  1. 1

    Check lubricating oil amount; replenish if required

  2. 2

    Only PULL UP on the manual plunger of the lubrication tank — never push down. The plunger falls on its own as oil moves out; pushing down can strip the plastic gears driving the lube pump.

    • HelmanCNCindustry_blog
      ONLY PULL UP on the manual plunger on the lubrication tank, as the plunger will fall on its own as it pushes oil out to the machine. If you push down, you can strip the little plastic gears that drive the lube pump, caus…
  3. 3

    If the reservoir was run too low, purge air from distribution lines before resuming operation

    • HelmanCNCindustry_blog
      If the lube oiler was allowed to run too low, there is a possibility that there is air in the line, and the system would have to be purged before normal operation would be allowed to continue.

Additional notes

The 'pull up only' tip is the veteran-shop detail that distinguishes real notes from AI-slop.

Confidence: high · Specific mechanism (SP67 + fixed-time logic) + operationally specific remedy steps.

First sourced: 5/21/2026