Unfinished Tool Set
Tool 1 in the Tool Data page has not been configured, even though the program only calls T8. The T-32 requires Tool 1 to be set up before any other tool numb...
- Controls
- T-32, T-32B
- Machine series
- Quick Turn
Causes
Tool 1 in the Tool Data page has not been configured, even though the program only calls T8. The T-32 requires Tool 1 to be set up before any other tool numbers can be used.
- adammforum
I think I have this one licked. I did two things: 1) Set the date and time on the clock. 2) Set-up Tool 1. ... So, it appears T1 needs to be configured on this control to do any work?!
- adammforum
Letter suffix mismatch between the program tool call (e.g. T8A) and the Tool Data page (e.g. T8) — the fields must match exactly.
- Philabusterforum
like Ender said, there is nothing indicating a letter A. The fields need to match from the program to the tool data page.
- Philabusterforum
How to clear it
- 1
Open Tool Data (1) and Tool Data (2). Make sure Tool 1 has data entered even if the current program does not use it. Then re-press Check Continue.
- adammforum
When I set tool 1, I wrote another short program and had T1 as roughing and T8 as finishing, and it worked. Then I went back to my other program and set it to be T1 and T8, and it worked there too. Then I set my original…
- adammforum
- 2
Verify every tool letter suffix in the program matches the Tool Data page exactly — if the program says T8A, the Tool Data row must read T8A (or both must be plain T8).
- EnderDRMforum
Cancel the letter designation in the program, Make "T8A" "T8".
- EnderDRMforum
Confidence: high · Two independent causes named in the same thread (T1-must-be-configured + letter-suffix mismatch), operator confirmed both fixes resolved the alarm, plus Philabuster (Diamond member) corroborated the letter-suffix point.