ALARM 33
SERVO MALFUNCTION 2 (&0000004D, &0004, &0021)
Loose contact inside the control board at the Z-axis encoder connection — random vibration triggered the alarm intermittently.
- Controls
- SmoothG
- Machine series
- unspecified Mazak with MDS-E/MDS-EH drives
Causes
Loose contact inside the control board at the Z-axis encoder connection — random vibration triggered the alarm intermittently.
- Fabian Achavalyoutube
The root cause on this case was lose contact inside the control board where the Z axis encoder is connected. Random vibrations triggered the alarm.
- Fabian Achavalyoutube
How to clear it
- 1
Replace the affected servo drive with a known-good unit. Original drive can be sent out for refurbishment.
- Fabian Achavalyoutube
The drive was replaced with a brand new one. Original drive is going to be refurbished.
- Fabian Achavalyoutube
Additional notes
Channel author notes 'There's room for improvement on the assembly design' — implying this is a known weak connection point on the drive.
Confidence: medium · 1 detailed YouTube case study from a Mazak service tech; root cause identified and fix verified, but only a single source.